Contact us
DISCOUNTED
PIX_X_tra_XPA_kilerem.jpg
DISCOUNTED
pix_x_tra_xpa_kilerem_v-belt.jpg

Description

V-belt XPA 2800 - 13x10 MM - PIX X'tra ® for industrial belt drives with XPA profile

V-belt XPA 2800 - 13x10 MM - PIX X'tra ® is a raw edged and Cogged V-belts from the PIX X'tra® series. It is intended for belt drives where the profile, length and pulley groove must match exactly to ensure stable operation. This variant has profile XPA, goal 13x10MM, effective length Width 2800 mm, inside length L 2755 mm and external length Width 2818 mm.

XPA is a medium profile in the XP series and is a relevant belt type when the pulleys are intended for a narrow Cogged V-belts with the dimensions 13x10 MM. The practical advantage of the correct profile is that the belt should neither bottom out in the groove nor be too high. When the profile fits, the load is better distributed on the sides of the belt, and the belt drive has a better opportunity to run smoothly.

Product data

  • Profile: XPA
  • Goal: 13x10MM
  • Effective length: Width 2800 mm
  • Inner length: L 2755 mm
  • External length: Width 2818 mm
  • Series: PIX X'tra® Molded Raw Edge Cogged Belts
  • Construction: raw edge and Cogged V-belts
  • Profile angle according to PIX data sheet: 36° ± 1°
  • Mark: PIX

Length specifications

The three length specifications describe the belt's geometry from each measurement position. L 2755 mm describes the inner length, Width 2800 mm is the effective length, and Width 2818 mm is the outer length. The difference between them is due to the geometry of the belt and the measurement method. Therefore, belts with almost the same outer dimensions can still have different technical specifications.

When a belt is specified from an older marking, it is usually best to compare both the letter profile and length designation. A belt marked as XPA 2800 should not be confused with another profile of the same nominal length. Therefore, consider both Li, Ld and La along with the profile and dimensions.

With Ld 2800 mm, the belt is a very long variant in this product group. Long belts require special attention to alignment, correct tensioning and the quality of the pulleys, because small deviations can propagate over a larger belt length.

Construction and technical features of PIX X'tra®

The PIX data sheets describe the construction with a special textile/fabric layer as a cover, a cushion rubber compound around the belt's working area, polyester cord as a tensile member and an EPDM-based compression part. In practice, this means that the belt should not only be assessed on its length. The internal construction is important for strength, flexibility, heat management and stability under load.

The main technical features of the PIX series are the timing flexibility, higher heat dissipation than a classic wrapped belt and the possibility of working in compact belt drives when the rest of the drive is correctly dimensioned. The series is also specified as antistatic, oil and heat resistant and REACH and RoHS compliant. These features are particularly relevant in machines where the belt runs for many times and is not only used occasionally.

For the XPA profile, the PIX data sheet states the length range 550–5000 mm. This belt with Ld 2800 mm is in the range 550–3000 mm, where the data sheet states a length tolerance of ±6 mm and a set tolerance of 2 mm. The tolerances are relevant when replacing, especially if several belts are to run in parallel or if the center distance can only be adjusted to a limited extent.

Use for the XPA profile

The operating situation has a great impact on the belt's lifespan: is the belt running constantly, are there many starts/stops, is the load even, and are the pulleys clean and in good condition? This XPA belt is designed for mechanical power transmission, but lifespan and operation still depend on alignment, tension, temperature, pulley quality, and whether the belt is installed without damage.

This XPA belt is relevant in moderate load applications where the belt must provide stable power transmission without taking up as much space as an XPB or XPC profile. In operation, the pulley groove, the belt cross-section and the timing construction are important for the contact between the belt and pulley. Profile and length must match, as correct length does not compensate for incorrect cross-section.

Profile and pulley compatibility

XPA belongs to the same narrow profile family as SPA, but the belt has its own technical specification with a timing, raw-edge construction. The belt works with side contact in the pulley groove, and the correct groove profile is necessary for the contact surface, friction and load to be distributed correctly. Incorrect cross-section or skewed pulleys can cause overheating, noise, slippage and uneven wear.

The technical identification consists of the combination XPA, 13x10MM, Width 2800 mm, L 2755 mm, Width 2818 mm and PIX X'tra®The combination distinguishes the item from nearby V-belts with other profiles, other length standards or a different construction.

Installation and operation

A new belt should be installed in clean, dry and undamaged pulleys. Oil, old belt dust, rust or sharp edges can shorten the life. Alignment between the pulleys is also important. Even a good belt can quickly wear out if the pulleys are misaligned or if the belt is forced to work sideways.

After start-up, it is wise to listen for abnormal noise and feel for abnormal heat when it is safe to do so. Slippage, whining, vibrations or black belt dust may indicate incorrect tension, incorrect profile, worn pulleys or excessive load. The fault should be found before the machine continues to run for a long time.

During continuous operation, the belt should be evaluated for ctiming bars, heavily worn side faces, glazing, frayed edges, and signs of overheating. If the belt repeatedly needs to be retensioned, it is often an indication that either the belt, the pulleys, or the setup itself should be examined. Replacing the belt alone does not always solve the cause of the problem.

During operation, the belt does not only function as a length indicator, but as a dimensionally stable component in a mechanical belt drive. The XPA profile, the width/height 13x10 MM and the effective length Ld 2800 mm form the basis for the belt's placement in the groove. The timing underside helps the belt around the pulleys, while the rough side surfaces transmit the force. The combination is particularly relevant when smooth running and limited heat generation are important for the service life of the system.

The raw edge construction gives the belt direct working surfaces against the pulley. Together with the polyester tension member and the serrated underside, this contributes to a design designed for mechanical power transmission under varying operating conditions.

Technical questions about XPA V-belts

What does XPA 2800 mean on this belt?

XPA is the profile designation and 2800 refers to the effective length Ld in millimeters. For this item, this means that the belt is specified as an XPA profile with dimensions 13x10 MM, Li 2755 mm, Ld 2800 mm and La 2818 mm.

Why does a new V-belt get hot?

Heat is often caused by incorrect tension, misaligned pulleys, worn grooves, excessive load or incorrect profile. A correctly specified belt can still have a short life if the belt drive is not adjusted correctly.

Is external length the same as effective length?

No. La is the external length, while Ld is the effective length. They must not be mixed up because the difference may be enough to prevent the belt from being tensioned correctly.

What conditions affect the operation of the belt?

Profile, dimensions, Ld, Li, La, pulley groove, number of belts in the drive and machine operation all affect the load on the belt. When these conditions match, the belt works more stably and has a longer service life.

What do Ld, Li and La mean on this V-belt?

Ld is the effective length and is the length stated in the product name. Li is the inside length, and La is the outside length. The three measurements are used to compare belts because manufacturers and older belt markings do not always use the same length designation.

Is the length alone enough to describe the belt?

No. The length is important, but the profile is at least as important. A belt with the correct length but the wrong profile can lie incorrectly in the pulley, causing poor contact, heat, noise and a shorter life.

When making technical comparisons, length, profile, cross-section and the product's Li, Ld and La should be viewed together. This makes the difference between internal, effective and external length clear and reduces the risk of confusion between adjacent belt sizes.

Overall rating: V-belt XPA 2800 - 13x10 MM - PIX X'tra ® is specified with profile XPA, dimensions 13x10 MM, effective length Ld 2800 mm, inner length Li 2755 mm and outer length La 2818 mm. The belt belongs to the PIX X'tra® series and is designed as a raw-edged, Cogged V-belts for mechanical power transmission.

Back to: XPA V-belts - 13x10 MM

Recently Viewed Products